ANSI SCTE 146-2017 pdf download.Outdoor “F” Female to “F” Female Inline Splice
1.1. Scope
The purpose of this document is to recommend mechanical and electrical standards for 75 ohm broadband radio frequency (RF) devices whose purpose is to provide an outdoor inline connection between two type “F” male connectors that conform to ANSI/SCTE 123; Specification for “F” Connector, Male, Feed- Through or ANSI/SCTE 124; Specification for “F” Connector, Male, Pin Type and ANSI SCTE 160, Specification for Mini F connector male Pin type. The mechanical configuration is designed to accommodate sealing rings for external applications. This specification is not intended to restrict any manufacturer’s innovation and improvement. The specification may be amended in the future as deemed appropriate.
2. Informative References
The following documents might provide valuable information to the reader but are not required when complying with this document.
3. Compliance Notation
This word or the adjective“required” means that the item is an absolute requirement of this document. This phrase means that the item is an absolute prohibition of this document. This word means the value specified shall never be used. This word or the adjective“recommended’ means that there may exist valid reasons in particular circumstances to ignore this item, but the full implications should be understood and the case carefully weighted before choosing a different course. This phrase means that there may exist valid reasons in particular circumstances when the listed behavior is acceptable or even useful, but the full implications should be understood and the case carefully weighed before implementing any behavior described with this label. This word or the adjective“optional? means that this item is truly optional. One vendor may choose to include the item because a . particular marketplace requires it or because it enhances the product, for example; another vendor may omit the same item. Use is permissible for legacy purposes only. Deprecated features may be removed from future versions of this document. Implementations should avoid use of deprecated features.
4.2. Center Conductor Mating
The center conductor contact of both ends shall accept male “F” connector center conductors whose diameters are between 0.0250” (0.64 mm) diameter and 0.0420” (1.07 mm) diameter. The junction shall have a minimum retention force of 50 grams with a 0.0320” (0.812 mm) diameter conductor inserted after the contact is mated 25 times with a center conductor whose diameter is 0.0403” (1.02 mm) when tested in accordance to IPS TP 417, Test Method for F Connector Center Conductor Retention.
5. Electrical
5.1. Bandwidth
Bandwidth shall be a minimum of 5 MHz to 1,218 MHz.
Unless otherwise specified, all performance parameters listed shall be tested in this frequency range.
5.2. Insertion Loss
Shall not exceed 0.1 dB for frequencies between 5 MHz and 600 MHz, 0.2 dB, for frequencies between 600 MHz and 1,002 MHz, and 0.25 dB for frequencies between 1002 MHz and 1,218 MHz when tested in accordance to ANSI/SCTE 144 2012, Test Procedure for Measuring Transmission and Reflection
5.3. Return Loss
Shall be no worse than 30 dB, when tested in accordance to ANSI/SCTE 04, ANS Test Method for ”F” Connector Return Loss or ANSI/SCTE 144 Procedure for Measuring Transmission and Reflection.
5.4. Shielding Effectiveness
The shielding effectiveness of the assembled components shall be a minimum of 100dB, when tested in accordance with ANSI/SCTE 48-1, Test Method for Measuring Shielding Effectiveness of Passive and Active Devices Using a GTEM Cell.
5.5. Surge Withstand
The surge withstand when measured in accordance with ANSI/SCTE 81 shall be a minimum of IEEE C62.41-1991 Category A3 Ring Wave, 6KV, 200 Amps.
5.6. Center Conductor Contact Resistance
The center conductor junction of the female to male F center conductor shall have a DC contact resistance of less than 25 milliohms after the testing performed in IPS TP 417 and then tested in accordance to ANSI/SCTE 103.
5.7. Outer Conductor Contact Resistance
The outer conductor junction of the indoor female “F” port to male F connector shall have a DC contact resistance less than 10 milliohms when tightened to 40 lb.-in. and tested to ANSI/SCTE 103.
5.8. Current Carrying Capacity
The center conductor junction of the outdoor female “F” port to male F center conductor shall be capable of carrying a minimum of 1 ampere DC continuous current at an ambient temperature of 40°C without degradation.ANSI SCTE 146-2017 pdf download